The first real cold week of the season brings a new kind of call for HVAC companies that install heat pumps. The system isn't broken, exactly. The homeowner just doesn't trust it. "The air coming out feels cool." "The outside unit stopped and started making a noise." "The backup heat keeps coming on." "My bill went up."

Some are real faults. Many are a heat pump doing what it's designed to do in a Saskatoon winter. Either way, the company that gives a straight answer is the one that books the visit. Here's how to handle those calls, using Natural Resources Canada's guidance.

Know the three explanations before you pick up

Natural Resources Canada's homeowner guide, Heating and cooling with a heat pump, covers most of what winter callers ask about.

The air feels cooler than a furnace. The guide says air-source heat pumps generally deliver a higher volume of warm air, heated to a lower temperature, normally between 25 and 45°C, while furnace systems heat air to between 55°C and 60°C. It notes that people switching from a furnace may notice this. That one fact settles a lot of calls.

The outdoor unit goes quiet, then starts again. The guide explains the defrost cycle: when the outdoor temperature is near or below freezing, moisture freezes on the outdoor coil, and the heat pump switches into defrost mode to melt it. During defrost the outdoor fan is shut off. It also says supplementary heating may be needed while the heat pump is defrosting.

The backup heat comes on. The guide explains the thermal balance point, the outdoor temperature below which the heat pump can supply only part of the heat the house needs. It says the vast majority of air-source heat pumps have a minimum operating temperature, which for newer models can range from -15°C to -25°C, and that below it a supplemental system must provide the heat. NRCan's heat pumps page adds that cold climate air source heat pumps can operate when outdoor air temperatures are as cold as -30°C, and that colder than that, supplemental heating may be required.

So a caller hearing the backup kick in on a very cold night is often hearing the system work as designed. Say so, and offer a visit if anything else sounds off.

Sort the call in the first minute

A few questions tell you whether it's an explanation, a settings fix or a service call:

  • Is the house holding temperature, or is it getting colder?
  • Is it a ducted system with a furnace, or a ductless unit?
  • What's the outdoor unit doing: running, stopped, iced over?
  • Is there heavy ice or snow built up around the outdoor unit?
  • When was the filter last changed or cleaned?
  • Did anyone change the thermostat schedule recently?
  • Name, callback number and address

If the house is losing heat and the backup isn't keeping up, that's a no-heat call. Treat it like one.

Settings that cause "it's not working" calls

The NRCan guide gives two settings tips worth knowing on the phone.

First, heat pumps respond more slowly than furnaces, so they struggle with deep temperature setbacks. The guide recommends setbacks of not more than 2°C, or a smart thermostat that starts recovery early. A deep overnight setback can mean a cool morning and the backup running hard.

Second, for systems with electric supplementary heat, the guide recommends setting the supplemental system 2°C to 3°C below the heat pump's set-point so the heat pump does most of the work. It says to consult the installation contractor on the right set-point. That's you, and it's a reason to book a visit.

Book the maintenance visit

The guide says to have a qualified contractor do annual maintenance, to change or clean the air filter every 3 months, and to keep vents and registers clear of furniture and carpeting. It also says undersized systems lean more on the supplemental heat, while oversized ones cycle on and off in milder weather.

So a winter call is a natural moment to offer a check-up: "We can come out, check the settings, the filter and the outdoor unit, and make sure the backup is set where it should be." If you run a maintenance plan, heat pumps belong on it. Our guide to setting up an HVAC maintenance plan covers how.

Quote calls from homeowners thinking about one

Winter also brings "should I get a heat pump?" calls. NRCan's heat pumps page gives homeowners a list of questions to ask a contractor, including the model and AHRI number, how the system will be sized, where the units will go, the sound level rating, and the warranty. Have answers ready for each. The page also says proper selection, sizing and installation are critical, and that undersizing or oversizing can make a system more costly and less efficient.

Adding a heat pump can mean a new electrical load, so loop in an electrician early if the panel looks tight. Our post on panel upgrade calls covers that side.

Catch the calls you'd otherwise miss

Heat pump questions come in on cold evenings. If they reach voicemail, many callers try the next company instead. Our post on furnace season explains why the first to answer usually wins.

A short text after a missed call keeps them with you: "Sorry we missed you. Is the house staying warm? Reply with what your heat pump is doing and we'll get back to you."

Where Ascent X fits

Ascent X answers every call, even at 2am, texts you the details, texts back anyone whose call gets missed, and sends review requests after the job. On Starter, you get the call answered and the details by text, and you book the job yourself. Plans from C$397/month, plus a one-time setup fee. The details are on our pricing page.

If you'd like help writing a phone script for heat pump calls at your HVAC company, ask for a free call back. We'll look at how your calls are covered today and what we'd change first.